Emergency Contingency Procedures ECP - Matrix Hose Burst |
Doc No.: ECP-A14 Revision: 01 Date: 15 Oct 2024 Issued by: DPA Approved by: MD |
.
Note:
- Hardcopy to be maintained on bridge.
| Action to be taken | Bridge Team | Technical Team | Emergency Squad | Watch Officer | Office |
|---|---|---|---|---|---|
| Sound alarm - General | ⚫ | ⚫ | ⚫ | ||
| If in port - advise terminal | ⚫ | ⚫ | ⚫ | ||
| Stop cargo / bunker operations - activate emergency shut down | ⚫ | ⚫ | |||
| Start fire pumps | ⚫ | ||||
| Assure accommodation ventilation is in full recirculation | ⚫ | ||||
| Shut all cargo system valves | ⚫ | ⚫ | |||
| Operate deck water spray system | ⚫ | ||||
| Muster crew - conduct tally of personnel. Ensure crew provide emergency gear | ⚫ | ⚫ | ⚫ | ||
| If at sea - consider alteration of course or speed to carry vapour cloud away from ignition sources or accommodation / personnel, is gas toxic | ⚫ | ||||
| Advise Company by emergency phone followed by message and advise charterers | ⚫ | ||||
| Respond as per VRP / SOPEP / SMPEP as applicable | ⚫ | ⚫ | |||
| If at sea - have ready at radio details of ship's position and any other information for a distress / urgency safety message | ⚫ | ||||
| Prohibit all smoking | ⚫ | ⚫ | ⚫ | ⚫ | |
| Advise engine room and emergency parties of situation | ⚫ | ⚫ | ⚫ | ⚫ | |
| Preserve VDR / SVDR records if not automatically protected | ⚫ |