Emergency Contingency Procedures
ECP - Matrix
Fire
Doc No.: ECP-A2
Revision: 01
Date: 15 Oct 2024
Issued by: DPA
Approved by: MD

.

Note:


Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Sound general alarm
If in port - advise terminal
Stop air conditioning / ventilation system
If at sea - consider alteration of course or speed to facilitate firefighting and dispersion of any un-ignited vapor
If vessel is unable to manoeuvre due to exceptional circumstances, display ‘Not under command’ signal (as per COLREGS Rule 27). Change the navigation status on the AIS
Muster crew - conduct tally of personnel. Ensure staff provide emergency equipment
Advise fire parties of situation / location
If at sea - advise nearest coast state and alert vessels in vicinity
Advise Company by emergency phone followed by message and advise charterers
Coordinate Fire Fighting, Lightering, & Salvage Services
Notify owners, P&I Club, etc. as per contingency plan

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Call Master
Assess proximity of navigational hazards, including traffic, and manoeuvre the ship as appropriate
Broadcast Urgency or Distress message, as appropriate
Maintain log/records of events and decisions
Preserve VDR / SVDR records if not automatically protected
In case of fire
In case of fire - Engine Room – Checklist Main Engine Failure, complete as appropriate
Steering Gear Room – Checklist Steering Failure, complete as appropriate
Generator Compartment – Checklist Total Electrical Power Failure, complete as appropriate

Accommodation Spaces / Galley

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Refer to Accommodation Plans for understanding of the layout
Isolate Electrical Circuits
Conduct Boundary Cooling from all Six Sides
In Galley Fires, preferred means if extinguishing would be Fire Blanket /CO2 / Dry powder to avoid Boil over

Engine Room

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Activate Emergency Fuel trips etc.
Confirm Emergency Power & Fire pump have been started
Conduct Boundary Cooling from all Six Sides
If the Fire is too large, Evacuate Engine room and use fixed CO2 / Foam

Cargo fire on deck / cargo tank

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Stop any Cargo Operations. Activate Emergency Shut down, shut all Cargo valves
Refer to MSDS Sheets
Activate deck and bridge and front water sprays, foam systems, Inert Gas system, Steam etc. as applicable

Pump Room

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Activate Emergency trips for all cargo pumps
Confirm all Cargo System Valves shut to isolate the pump room
Conduct Boundary Cooling
If the Fire is too large, evacuate pump room and use fixed CO2 / Foam