Emergency Contingency Procedures
ECP - Matrix
Fire
Doc No.: ECP-A2
Revision: 01
Date: 15 Oct 2024
Issued by: DPA
Approved by: MD

.

Note:


Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Sound general alarm ⚫ ⚫
If in port - advise terminal ⚫ ⚫
Stop air conditioning / ventilation system ⚫
If at sea - consider alteration of course or speed to facilitate firefighting and dispersion of any un-ignited vapor ⚫
If vessel is unable to manoeuvre due to exceptional circumstances, display ‘Not under command’ signal (as per COLREGS Rule 27). Change the navigation status on the AIS ⚫ ⚫
Muster crew - conduct tally of personnel. Ensure staff provide emergency equipment ⚫ ⚫ ⚫
Advise fire parties of situation / location ⚫ ⚫ ⚫
If at sea - advise nearest coast state and alert vessels in vicinity ⚫
Advise Company by emergency phone followed by message and advise charterers ⚫
Coordinate Fire Fighting, Lightering, & Salvage Services ⚫
Notify owners, P&I Club, etc. as per contingency plan ⚫

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Call Master ⚫
Assess proximity of navigational hazards, including traffic, and manoeuvre the ship as appropriate ⚫
Broadcast Urgency or Distress message, as appropriate ⚫
Maintain log/records of events and decisions ⚫
Preserve VDR / SVDR records if not automatically protected ⚫
In case of fire
In case of fire - Engine Room – Checklist Main Engine Failure, complete as appropriate ⚫ ⚫
Steering Gear Room – Checklist Steering Failure, complete as appropriate ⚫ ⚫
Generator Compartment – Checklist Total Electrical Power Failure, complete as appropriate ⚫ ⚫

Accommodation Spaces / Galley

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Refer to Accommodation Plans for understanding of the layout ⚫
Isolate Electrical Circuits ⚫
Conduct Boundary Cooling from all Six Sides ⚫ ⚫
In Galley Fires, preferred means if extinguishing would be Fire Blanket /CO2 / Dry powder to avoid Boil over ⚫

Engine Room

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Activate Emergency Fuel trips etc. ⚫
Confirm Emergency Power & Fire pump have been started ⚫
Conduct Boundary Cooling from all Six Sides ⚫
If the Fire is too large, Evacuate Engine room and use fixed CO2 / Foam ⚫ ⚫ ⚫

Cargo fire on deck / cargo tank

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Stop any Cargo Operations. Activate Emergency Shut down, shut all Cargo valves ⚫ ⚫
Refer to MSDS Sheets ⚫ ⚫
Activate deck and bridge and front water sprays, foam systems, Inert Gas system, Steam etc. as applicable ⚫ ⚫

Pump Room

Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Activate Emergency trips for all cargo pumps ⚫
Confirm all Cargo System Valves shut to isolate the pump room ⚫ ⚫
Conduct Boundary Cooling ⚫
If the Fire is too large, evacuate pump room and use fixed CO2 / Foam ⚫ ⚫ ⚫