Emergency Contingency Procedures
ECP - Matrix
Methanol Fuel Leak (Engine Room)
Doc No.: ECP-A45
Revision: 01
Date: 15 Oct 2024
Issued by: DPA
Approved by: MD

Note:


Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Sound general alarm ⚫
Operate inert system to purge the fuel system lines of vapour build-up ⚫ ⚫
Donning of Chemical Suits (with BA Sets) for Emergency Squad ⚫ ⚫
If methanol leak is detected and without internal sensors alerting same, then emergency stop of Methanol supply. ME switches to pure DO mode. ⚫
Purge system, reset alarm system, monitor situation and identify fault/s. ⚫
Fire pumps in readiness and portable dry powder, CO2 extinguisher system ready for possible outbreak of fire ⚫ ⚫
Muster crew – conduct tally of personnel ⚫ ⚫ ⚫
Advise Bridge and emergency parties of situation ⚫
If at sea – advise nearest coast state and alert vessels in vicinity as authorized by Master ⚫
Commence notifications to Company as per Incident reporting procedures ⚫ ⚫
Refer to MSDS emergency procedures ⚫ ⚫
Preserve VDR / SVDR records if not automatically protected ⚫