Emergency Contingency Procedures ECP - Matrix Methanol Fuel Leak (Engine Room) |
Doc No.: ECP-A45 Revision: 01 Date: 15 Oct 2024 Issued by: DPA Approved by: MD |
Note:
- Hardcopy to be maintained on bridge.
| Action to be taken | Bridge Team | Technical Team | Emergency Squad | Watch Officer | Office |
|---|---|---|---|---|---|
| Sound general alarm | ⚫ | ||||
| Operate inert system to purge the fuel system lines of vapour build-up | ⚫ | ⚫ | |||
| Donning of Chemical Suits (with BA Sets) for Emergency Squad | ⚫ | ⚫ | |||
| If methanol leak is detected and without internal sensors alerting same, then emergency stop of Methanol supply. ME switches to pure DO mode. | ⚫ | ||||
| Purge system, reset alarm system, monitor situation and identify fault/s. | ⚫ | ||||
| Fire pumps in readiness and portable dry powder, CO2 extinguisher system ready for possible outbreak of fire | ⚫ | ⚫ | |||
| Muster crew – conduct tally of personnel | ⚫ | ⚫ | ⚫ | ||
| Advise Bridge and emergency parties of situation | ⚫ | ||||
| If at sea – advise nearest coast state and alert vessels in vicinity as authorized by Master | ⚫ | ||||
| Commence notifications to Company as per Incident reporting procedures | ⚫ | ⚫ | |||
| Refer to MSDS emergency procedures | ⚫ | ⚫ | |||
| Preserve VDR / SVDR records if not automatically protected | ⚫ |