Emergency Contingency Procedures
ECP - Matrix
Methanol Fuel Leak (Engine Room)
Doc No.: ECP-A45
Revision: 01
Date: 15 Oct 2024
Issued by: DPA
Approved by: MD

Note:


Action to be taken Bridge Team Technical Team Emergency Squad Watch Officer Office
Sound general alarm
Operate inert system to purge the fuel system lines of vapour build-up
Donning of Chemical Suits (with BA Sets) for Emergency Squad
If methanol leak is detected and without internal sensors alerting same, then emergency stop of Methanol supply. ME switches to pure DO mode.
Purge system, reset alarm system, monitor situation and identify fault/s.
Fire pumps in readiness and portable dry powder, CO2 extinguisher system ready for possible outbreak of fire
Muster crew – conduct tally of personnel
Advise Bridge and emergency parties of situation
If at sea – advise nearest coast state and alert vessels in vicinity as authorized by Master
Commence notifications to Company as per Incident reporting procedures
Refer to MSDS emergency procedures
Preserve VDR / SVDR records if not automatically protected