Emergency Contingency Procedures ECP - Matrix Marine Scrubber (Exhaust Gas Cleaning System) Failure |
Doc No.: ECP-A47 Revision: 01 Date: 15 Oct 2024 Issued by: DPA Approved by: MD |
Note:
- Hardcopy to be maintained on bridge.
| Action to be taken | Bridge Team | Technical Team | Emergency Squad | Watch Officer | Office |
|---|---|---|---|---|---|
| Notify Master | ⚫ | ||||
| Report equipment failure | ⚫ | ⚫ | |||
| Verify vessel's position (Time, location and details of event) | ⚫ | ⚫ | |||
| If main engine failure – comply as per TGM 2.13.1 A24 MATRIX – Main engine failure | ⚫ | ⚫ | ⚫ | ||
| Assess if M/E need to be stopped or consider for controlled stop if required | ⚫ | ⚫ | |||
| Determine cause of failure and estimated completion time of repair. Refer to TGM 2.10.11 A16 – Scrubber Operation / Malfunctioning | ⚫ | ||||
| Determine if ship's crew capable to repair the equipment and put back into a compliant condition within one hour | ⚫ | ⚫ | |||
| If equipment cannot be rectified within 1 hour, changeover to compliant fuel / LSMGO | ⚫ | ||||
| Monitor parameters of other machineries (Fuel temperature, viscosity, A/E, Boiler, etc). Log down entry in Annex VI record book | |||||
| Evaluate ROB of compliant fuel / LSMGO on board | ⚫ | ⚫ | |||
| If insufficient compliant fuel on board, propose an action plan for bunkering compliant fuel | ⚫ | ⚫ | |||
| Plan for equipment repair | ⚫ | ⚫ | |||
| Notify flag state and destination port authority on current status, bunkering and repair plan. Seek approval before consuming the non-compliant fuel oil | ⚫ | ⚫ | |||
| Log entry made (Deck logbook and Engine logbook, EGCS record book, etc.) | ⚫ | ⚫ | |||
| Preserve VDR / SVDR records if not automatically protected | ⚫ |